The cause of motor overload caused by the twin-screw air compressor main engine operation!
- 2018-10-26-


Attention!  The following situation will cause the current of the twin-screw air compressor main engine to be too high, and the current of the air compressor main engine is too high, which will cause overload shutdown failure, and will burn the motor in severe cases.

There are two main motors in the screw air compressor system: the main motor and the cooling fan motor.  If the motor current continues to exceed the upper limit set by the protection device, the protection device will automatically cut off the main power supply during the period of time to stop the air compressor. At this time, the current overload factor should be traced. After the fault is removed in time, the air compressor can be restarted. start up.

First, the main causes of the overload of the main motor of the screw air compressor are as follows:

The three-phase voltage of the air compressor is unstable, under-phase, and voltage is too low;

Adjusting the exhaust pressure to be higher than the rated pressure of the air compressor;

The overload protector of the air compressor has failed;

The bearing of the main motor is not refueled or the bearing is damaged;

Motor internal loss, phase loss operation;

The power supply voltage is too low, and the power line is imaginary;

The air filter is blocked;

The oil and gas separator has a blockage phenomenon;

Second, the main reasons for the overload of the fan electric host are:

The cooler is severely blocked;

Motor internal loss, phase loss operation;

The power supply voltage is too low and the power line is virtually connected.

Third, the role of the protection system when the temperature of the twin-screw air compressor is too high:

The air compressor system sets a higher exhaust temperature of 100 ° C. If it exceeds 100 ° C, the system cuts off the power by itself.

Common causes of excessive exhaust temperatures:

The cooler pipe is blocked;

The cooler fins are blocked by dirt;

The cooling fan stops running;

The ambient temperature is too high;

Less oil.

Fourth, the role of the twin-screw air compressor reverse phase protection system: When the phase sequence of the three-phase power supply connected to the air compressor is inconsistent with the phase sequence of the air compressor, the air compressor unit starts.  At this time, it is necessary to exchange any two of the three phases.